Transfer of allocated transmission capacities on auctions carried out by HOPS:
The participant to whom the transmission capacity is allocated on yearly and monthly auctions can fully or partially transfer its allocated transmission capacity for use to the other allocation participant via relevant Auction system according to the related auction rules.
The minimum amount of transmission capacity available to transfer to the other allocation participant is 1 MW.
Terms of Use of Allocated Transmission Capacities in Electric Power System of
Croatia:
- Valid registration licence to carry activities on energy market issued by HERA
- To obtain international EIC Code
- To sign Balance Responsibility Agreement with HOPS
- Electricity Market Participation Agreement with the Croatian Energy Market Operator
In accordance with Rules on Use of Cross-Border Transmission Capacities (further: Rules) deadlines for nominations on the borders with neighbouring system operators are:
Rules for nomination of cross border schedules for 2024. | ||||
---|---|---|---|---|
Country | Description | Long-term Capacities |
Short-term Capacities |
Intraday Capacities |
Business Type A03 | ||||
Slovenia (ELES) | Time / Quantity resolution * | 60 min / 1 MW | 60 min / 0,1 MW | 15 min / 0,1 MW *** |
Capacity Contract Type (CCT) | A04 (Yearly) / A03 (Monthly) | — |
A07 (I) *** | |
Capacity Agreement ID (CAI) | allocated by JAO | — |
allocated by XBID *** | |
Earliest possible nomination | — | — |
D-1 22:00 *** | |
Nomination Gate Closure | D-2 17:00 | — |
H-30 for H *** | |
Correct Cycle | D-2 17:00-18:00 | — |
N/A *** | |
Nomination procedure | n:m | — |
a:b *** | |
Hungary (MAVIR)**** | Time / Quantity resolution * |
— |
60min / 0,1 MW | 15 min / 0,1 MW |
Capacity Contract Type (CCT) |
— |
— |
— | |
Capacity Agreement ID (CAI) |
— |
— |
— | |
Earliest possible nomination |
— | — |
— | |
Nomination Gate Closure |
— |
— | — | |
Correct Cycle |
— |
— |
— | |
Nomination procedure |
— |
— |
— | |
Bosnia and Herzegovina (NOS BIH) | Time / Quantity resolution * |
60 min / 1 MW | 60 min / 1 MW | 60 min / 1 MW |
Capacity Contract Type (CCT) |
A04 (Yearly) / A03 (Monthly) | A01 (Daily) | A07(Intraday) | |
Capacity Agreement ID (CAI) |
allocated by SEE CAO | allocated by SEE CAO | allocated by NOSBIH | |
Earliest possible nomination |
— | D-1 10:00 | D-1 18:00 | |
Nomination Gate Closure |
D-1 08:00 | D-1 14:30 | H-45 for H | |
Correct Cycle |
D-1 08:00-08:30 | D-1 14:30-15:30 | — | |
Nomination procedure |
n:m | n:m | n:m | |
Serbia (EMS) | Time / Quantity resolution * |
60 min / 1 MW | 60 min / 1 MW | 60 min / 1 MW |
Capacity Contract Type (CCT) |
A04 (Yearly) / A03 (Monthly) | A01 (Daily) | A07(Intraday) | |
Capacity Agreement ID (CAI) |
allocated by JAO | allocated by JAO | allocated by EMS | |
Earliest possible nomination |
— | D-1 10:00 | D-1 18:00 | |
Nomination Gate Closure |
D-1 08:00 | D-1 14:30 | H-45 for H | |
Correct Cycle |
D-1 08:00-08:30 | D-1 14:30-15:30 | — | |
Nomination procedure |
n:m | n:m | n:m ** | |
* 60 minutes equals 4 identical quarter-hour-values, whereas 15 minutes result in different possible quarter-hour-values. Both 1MW and 1kW resolution requires 3 decimals.
** For single ID nomination, PTR holder is obligated to use whole amount of ID PTR with only one counterparty. *** Valid only for explicit allocation. **** Intraday capacity is implicitly allocated by XBID.
|
It is not possible to change the submitted plans of cross-border exchange upon the expiry of the above mentioned deadlines.